Slow JCT troubleshooting – Spectrum-X Ethernet (east-west fabric), hypothetical example

Hypothetical design and invented values. Values read from dashboards (Grafana/Prometheus, fabric telemetry, drop telemetry) are stated directly. CLI is shown only where it's the natural tool.

Context

Baseline (healthy) Value
Live all-reduce busbw, cross-node communicator 355 GB/s, stable
nccl-tests all-to-all, 8 nodes 41 GB/s
ib_write_bw per NIC 385 Gb/s

Phase A: live, job keeps running

A1. Live busbw (Grafana, NCCL Inspector)

Reading: cross-node comms degraded. The pattern is noisy, not a clean step, which suggests a congestion-dependent problem (loss/retransmits under load) rather than a hard fault.

A2. Straggler or transfer path? (straggler panel, GPU dashboard)

Reading: the transfer path, not a slow GPU.

A3. Physical health (fabric telemetry dashboard)

Reading: not physical. On Ethernet, A1-A3 together mean packets are being dropped, delayed or retransmitted under load. The next question is about the fabric: where is traffic dropped, and what traffic is it?

A4. What changed at onset? (change log, scheduler history)

Reading: a suspect, not yet evidence.

A5. Is the fabric dropping anything? (drop telemetry / WJH, switch counters)

Reading: drops confirmed. Which traffic?

A6. Which traffic class? (per-class counters on those ports)

Reading: RoCE traffic is arriving in the wrong class, so something is mis-marking it.

A7. Who sends it? (WJH drop records)

Reading: a single sender. Map the IP to a port.

A8. Where does it attach? (fabric telemetry: neighbor table + LLDP)

Reading: matches the A4 suspect. Only now does the investigation touch the host.

A9. Confirm on the host and find why

Host telemetry for su3-n17 rail 5: RDMA bytes go out on priority 0, not 3. RoCE retransmits are high, and congestion notifications handled are 0 (it gets no ECN-based congestion control). Config diff against a healthy node:

mlnx_qos -i eth5 | grep -i trust
cat /sys/class/infiniband/mlx5_5/tc/1/traffic_class
Node Trust traffic_class
su3-n16 (healthy) dscp 106 (DSCP 26 + ECN-capable)
su3-n17 pcp (empty)

The same drift is on all 8 NICs of su3-n17: the host QoS role didn't run on reimage. The job doesn't set NCCL_IB_TC, so NCCL used the node default.

Phase A conclusion, no drain so far: host-side QoS config drift on su3-n17. Its RoCE traffic is marked DSCP 0, lands in the lossy class, is dropped under congestion and retransmitted, and gets no ECN congestion control. Fabric hardware and switch config are fine.

Phase B: repair window agreed with the app team

RDMA queue pairs take their traffic class when the job initialises, so fixing the host requires a job restart anyway. That restart is the repair window.

B0. Take the node out

scontrol update nodename=su3-n17 state=drain reason="RoCE QoS not applied after reimage"

The job restarts on a spare. Grafana: live busbw 355 GB/s stable, step time 1.10 s.

B1. Confirm on su3-n17, and why pair tests mislead on Ethernet

Test Result Baseline Reading
GPU health (DCGM diag), single-node all-reduce Pass / 478 GB/s 480 GPU side fine
ib_write_bw pair, host memory 385 Gb/s 385 Normal
ib_write_bw pair, GPU memory 384 Gb/s 385 Normal
8-node all-to-all with su3-n17 24.6 GB/s 41 Fault reproduces under congestion
Same, without su3-n17 40.8 GB/s 41 Fault follows the node

Key point: a single uncongested flow never meets a full queue, so it is never dropped. Pair tests pass even with a QoS fault present. On Ethernet, reproduce with a congested pattern (all-to-all or incast).

B2. Fix

Apply the QoS role on su3-n17 via config management (trust DSCP, traffic class 106, all 8 NICs). Fix the reimage pipeline so the role always runs.

B3. Verify and return

scontrol update nodename=su3-n17 state=resume

Add a pre-flight check: a node's trust state and traffic class must match the golden config before it can take jobs.

Why a marking error on one node cost about 19% of JCT

Every collective includes channels to and from su3-n17. Its packets are dropped whenever a queue on the path fills, and each drop stalls that channel until the retransmit. The collective finishes only when the stalled channel does, so all 512 ranks wait. Drops depend on momentary congestion, so the slowdown is noisy, not a clean step.

Principle

IB vs. Spectrum-X: what changes

Aspect InfiniBand case Spectrum-X case
Typical fault signature Clean step, link rate/BER visible Noisy, congestion-dependent
Physical health check Finds it Clean
Key evidence Link rate, BER, symbol errors Drop telemetry, traffic class, DSCP, CNP/retransmits
Pair test Shows the fault Can pass with a fault present; needs a congested test
Locate the port Fabric topology / iblinkinfo Source IP → neighbor table → LLDP

Verify on your system